D&D ClariSea Auto Advance Upgrade Kit

The ClariSea fleece filter is a high efficiency water filtration system which effectively removes suspended particles such as micro algae, detritus, food, organic waste and gravel dust from the water column. Suitable for use in marine aquariums, freshwater aquariums, fish-breeding systems and propagation systems for corals.

DKK 1.615,28

Product not in stock - Estimated backorder time: 14 days

EAN

5060078023061
STOCK INFORMATION

Product not in stock - Estimated backorder time: 14 days

Payment methods
Shipping method

ABOUT THIS PRODUCT:

This product converts the SK-3000 Manual into an automatic model.
Allows automatic advance of dirty fleece
Improves filtration capacity
Multi-function smart controller
End of roll audible alarm
Filter jam/float error/water depth alarm
Contents
Allows automatic advance of dirty fleece
Improves filtration capacity
Multi-function smart controller
End of roll audible alarm
Filter jam/float error/water depth alarm

Buttons & Indicators
Motor button
• Manually advances fleece motor

Alarm button
Press alarm button for 1 – 2 seconds will turn off audible alarm, but alarm condition will still be present
Red LED still flashing.
Automatic advance of fleece disabled.
Motor button will still function as manual advance.
Pressing the alarm button for > 5 seconds/-

Full reset – completely clearing alarm state.
Disconnecting power/ performs reset as above.

Normal Operation
Initialisation (Power on or reset)/
• Blue/Red LED both flash for 5 times (audible alarm will sound with each flash).
• Blue LED will remain on.
Motor Advance/
Manual or automatic, Blue LED flashes

Possible Alarm Conditions/
Possible roll jam/motor failure (float held in up position)
• Red alarm LED will flash.
• Audible alarm will sound for 2 seconds every 5 seconds.
• Automatic advance of fleece disabled.
Possible fleece empty (float not triggered with a set time limit)
• Blue/Red LED both flashing, audible alarm will sound for 1 second every 2 seconds
• Automatic advance of fleece disabled.

Possible installation error (float not triggered with 48 hours)
• Red LED will flash at 10 second intervals (audible alarm will sound with each flash)
• Automatic advance of fleece disabled.